STM Article Repository

Magyari, Balázs and Kittka, Bálint and Goják, Ilona and Schönfeld, Kristóf and Szapáry, László Botond and Simon, Mihály and Kiss, Rudolf and Bertalan, Andrea and Várady, Edit and Gyimesi, András and Szokodi, István and Horváth, Iván Gábor (2024) Learning Curve for Starting a Successful Single-Centre TAVR Programme with Multiple Devices: Early and Mid-Term Follow-Up. Journal of Clinical Medicine, 13 (4). p. 1088. ISSN 2077-0383

[thumbnail of jcm-13-01088.pdf] Text
jcm-13-01088.pdf - Published Version

Download (978kB)

Abstract

We report 30-day, 1-year, and 3-year outcomes for a new TAVR programme that used five different transcatheter heart valve (THV) systems. Methods: From 2014 to 2020, 122 consecutive patients with severe aortic stenosis (AS) received TAVR based on the Heart Team decision. Outcomes were analysed for the whole study population and in addition the first 63 patients (Cohort A, 2014 to 2019) were compared to the last 59 patients (Cohort B, 2019 to 2020). Outcomes included VARC-2 definitions and device performance assessed via transthoracic echocardiography by independent high-volume investigators. Results: The mean patient age was 77.9 ± 6.1 years old, and 48 (39.3%) were male. The mean logistic Euroscore II was 4.2 ± 4.5, and the mean STS score was 6.9 ± 4.68. The systems used were as follows: Medtronic Corevalve Evolute R/PRO (82 patients—67.2%); Abbott Portico (13—10.6%); Boston Scientific Lotus (10—8.2%); Meril Myval (11—9%); and Boston Scientific Neo Accurate (6—5%). Access was transfemoral (95.9% of patients); surgical cut down (18% vs. percutaneous 77.8%); subclavian (n = 2); trans-axillary (n = 2); and direct aorta (n = 1). VARC-2 outcomes were as follows: device success rate 97.5%; stroke rate 1.6%; major vascular complication 3.3%; permanent pacemaker implantation 12.4%. At discharge, the incidences of grade I and II aortic regurgitation were 39.95 and 55.5%, respectively. At one year, all-cause mortality was 7.4% without admissions for valve-related dysfunction. The 3-year all-cause mortality and all-stroke rates were 22.9% and 4.1%, respectively. Between the 1-year and 3-year follow-ups, valve-related dysfunction was detected in three patients; one had THV system endocarditis that led to death. There was a remarkable but statistically non-significant decrease in mortality from Cohort A to Cohort B [four (6.3%) vs. one patient (1.7%), p = 0.195] and major vascular complications occurred at a significantly higher rate in the Cohort B [zero (0%) vs. four (6.8% patient, p = 0.036)]. Overall, we found that using multiple devices was safe and allowed for a learning team to achieve a high device success rate from the beginning (97.5%). Conclusions: TAVR with different THV systems showed acceptable early and mid-term outcomes for survival, technical success, and valve-related adverse events in high-risk patients with significant AS, even in the learning curve phase.

Item Type: Article
Subjects: GO for ARCHIVE > Multidisciplinary
Depositing User: Unnamed user with email support@goforarchive.com
Date Deposited: 15 Feb 2024 05:22
Last Modified: 15 Feb 2024 05:22
URI: http://eprints.go4mailburst.com/id/eprint/2145

Actions (login required)

View Item
View Item